Portal Enrollment for New Bidder  
  • Home
  • User Manual
    • Vendor Enlistment
    • Help Manual for Machine Setup
    • Help Manual for NxtCrypto Setup
    • Bid Preparation
    • Viewing of Opened Tenders
    • Clearing the Browser History
    • Bid submission Video
  • System Requirements
    • System Requirement Manual
    • Guideline For e-token
    • Download DC Setup
    • Download NxtCrypto Service Setup
    • Download Java Setup
    • List of Compatible eToken
    • Machine Setup Manual
    • Guidelines to enable service on DAE.
  • Digital Certificate Form
    • Important Points For Applying DSC
    • Online Application Procedure for DSC
    • PPT for DSC Enrollment
    • Subscription Form
  • FAQ
  • Test Certificate
  • Contact Us
Close

Login utility has been upgraded.All users please follow below steps::

1.Uninstall Nxt crypto set up from Control panel.

2.Uninstall Nxt crypto service set up from Control panel.

3.Download and install Dc setUp from System Requirements-->Download DC setup.

4.Download and install Nxtcrypto service SetUp from System Requirements-->Download NxtcryptoService setup.

5.Reset your browser.

6.Guidelines to enable service on DAE..Click here

NIT Tender Details
DPS/CPU/04/D1/2101/PT
09/02/2021
09/03/2021 14:30:00
09/03/2021 14:30:00
09/03/2021 15:00:00
NA
NA
Qualifying Requirement : NA
Sr. noItem CategoryItem DescriptionQty
1OTHERS MEASURING INSTRUMENTSSupply , Installation/Commissioning and Warranty of High Resolution Spectrometer: 1.Spectrometer: 1.1)Spectral Range (nm):300-800 1.2)Focal length:750mm 1.3)Aperture:≤F/9.7 1.4)Wavelength accuracy(center):0.03nm or better 1.5)Wavelength Repeatability:≤10 pm 1.6)Gratings:Triple grating turret 1.7)Grating Size:68mmX68mm or larger 1.8)Entrance ports:Two; the side(second) entrance port to be selectable by software controlled flip mirror 1.9)Slit:One port with motorized controlled slit via software & side entrance port with micrometer controlled slit. 1.10)Slit Width (both entrance):10micron to 2.5mm 1.11)Exit port:1 exit port for CCD 1.12)Interface:USB 1.13)Resolution:0.03nm or better with 1800 l/mm grating @500nm 1.14)Gratings- 3: i)Holographic grating 1800l/mm with peak at 480nm,ii)Holographic grating 1200l/mm with peak at 500nm, iii)600l/mm grating blazed at 500nm 1.15)Appropriate Flange to mount CCD 2.Low dark current,high sensitivity,Peltier Cooled CCD detector: 2.1)Active pixels:2048x512 2.2)Pixel size:13.5x13.5 µm or lesser 2.3)Image area:27.6mmx6.9mm with 100% fill factor 2.4)Minimum temperature with Air cooling at 20degC: -80degC or better, with capability to go down to -100degC with water cooling 2.5)QE between 500nm and 700nm>90%,back illuminated Visible CCD 2.6)Blemish specifications:Grade1 or better 2.7)Dark current,e-/pixel/sec:0.0002 or lower, to be tested and certified 2.8)Register well depth:>120000e- for high sensitivity mode;>500000e- for high capacity mode 2.9)Minimum Read noise(e-):2.5e- or better 2.10)CCD must operate in high sensitivity mode (electrons/count adjustable from 1-4)and high capacity mode (electrons/count adjustable from 4-16),with minimum 3 readout rates 50KHz,1MHz,3MHz 2.11)Maximum Spectral rate(spectra/sec)>100 full vertical bins 2.12)Linearity:Better than 99% 2.13)Digitization:16bit 2.14)Interface:USB 2.15)Latest data acquisition, control software(64bit,32bit Windows OS compatible) 2.16)CCD & Spectrometer to be compatible and controlled with same software 3.Miscellaneous: Annex.11

STORES OFFICER, CENTRAL STORES UNIT, DIRECTORATE OF PURCHASE AND STORES, B.A.R.C., TROMBAY, MUMBAI - 400 085.
Privacy Policy|Contact Us|Disclaimer
Best view in 1360x768 Resolution
NexProcure Extended Version 1.3.0
Copyright © 2019 e-tenders.in