Portal Enrollment for New Bidder  
  • Home
  • User Manual
    • Vendor Enlistment
    • Help Manual for Machine Setup
    • Help Manual for NxtCrypto Setup
    • Bid Preparation
    • Viewing of Opened Tenders
    • Clearing the Browser History
    • Bid submission Video
  • System Requirements
    • System Requirement Manual
    • Guideline For e-token
    • Download DC Setup
    • Download NxtCrypto Service Setup
    • Download Java Setup
    • List of Compatible eToken
    • Machine Setup Manual
    • Guidelines to enable service on DAE.
  • Digital Certificate Form
    • Important Points For Applying DSC
    • Online Application Procedure for DSC
    • PPT for DSC Enrollment
    • Subscription Form
  • FAQ
  • Test Certificate
  • Contact Us
Close

Login utility has been upgraded.All users please follow below steps::

1.Uninstall Nxt crypto set up from Control panel.

2.Uninstall Nxt crypto service set up from Control panel.

3.Download and install Dc setUp from System Requirements-->Download DC setup.

4.Download and install Nxtcrypto service SetUp from System Requirements-->Download NxtcryptoService setup.

5.Reset your browser.

6.Guidelines to enable service on DAE..Click here

NIT Tender Details
DPS/CPU/04/A2/2540
08/02/2021
08/03/2021 14:30:00
08/03/2021 14:30:00
08/03/2021 15:00:00
NA
NA
Qualifying Requirement : AS PER TENDER
Sr. noItem CategoryItem DescriptionQty
1ELECTRONICS EQUIPMENTSUPPLY AND WARRANTY OF: Indent Specifications We have requirement of portable mini NIM crate (Quantity: 1 No). Please find the specifications as mentioned below 1. Portable mini NIM crate housing 7 slot (5 free slots with power supply) for single width NIM modules . 2. Mains input: 230 VAC, 50-60 Hz. 3. Max. Total Output Power: 150 W. 4. Fuse External: External 2 A, class T (230 VAC). 5. Power requirements: 280W at full load. 6. Output power: 5 A @ ±6V 3 A @ ±12 V 1.5 A @ ±24 V. 7. Load Regulation: < 0.5 % for 10-100% load change, < 0.02 % for ±10% line change. 8. Ripple: < 5 mVpp for ±6 V, < 8 mVpp for ±12 V, < 10 mVpp for ±24 V. 9. Transient response recovery: 0.15 ms for recovery to ±1% of voltage for 10-100% load change. 10. Output Impedance: 0.6 mῼ static. 11. Over Voltage Protection: Trip Off when the output voltage > 130% of nominal voltage. 12. Under Voltage Protection: Trip Off when the output voltage < 70% of nominal voltage. 13. Over Current Protection: Trip Off when current: >6A@+24V, >2A@-24V, >6A@+12V, >3.75A@-12V, > 10A@±6V. 14. Over Temperature Protection: Trip Off when temperature > 75° C. 15. Should have LED signal for FAIL status. 16. Should have stable operation between 0 to 45°C without de-rating.1

STORES OFFICER, CENTRAL STORES UNIT, DIRECTORATE OF PURCHASE AND STORES, B.A.R.C., TROMBAY, MUMBAI - 400 085.
Privacy Policy|Contact Us|Disclaimer
Best view in 1360x768 Resolution
NexProcure Extended Version 1.3.0
Copyright © 2019 e-tenders.in